Skip to main content

Required

ELECTRICAL PROJECT ENGINEER

Job descriptionYou will be part of our team within the electrical group and mainly work on minor projects within the Oil & Gas and wind power industry. You will be involved in design of control and distribution panels.
Travelling both site and offshore can be anticipated.

Qualifications:• Graduated Engineer or Certified Electrician/Technician
• Experience with explosion proof enclosures
• Knowledge of PC Schematic
• Writing and speaking high standard English
• Good health for work in the Marine/Offshore environment
• Minimum three years of experience with project engineering.

Personal qualifications:You will be part of a dynamic worldwide team of engineers which will require your ability to cooperate with local engineers as well as cooperate with our engineers around the world.

You have a personal drive and can work independently and well-structured on various projects in a busy organisation.


ELECTRICAL ENGINEER


Job description
We are looking for employees at all position levels and with experience in:
  • Lead engineers with profound oil / gas experience and within the disciplines in the project.  This function also has a leading technical role for other project engineers
  • Generalists who are familiar with most of the fields within the discipline. 
We are looking for employees for engineering tasks in the following areas:
Condition monitoring / vibration monitoring on structures and rotating equipment
Turbine and generator upgrade of controller and controller system.
Primary tasks: 
  • System description and technical specifications
  • Making of cable lists, signal lists, equipment lists, component lists
  • Equipment layout, cable layout
  • Data sheets
  • Inter-connection drawings, block diagrams, single line diagram
  • Control panel design (specification)
  • General project documentation 
Qualifications:
  • Knowledge of controllers and monitoring of / from industrial facilities
  • Knowledge of and experience with the tasks listed above
  • Knowledge of ATEX/EX 
Additionally, for condition monitoring:
  • Experience with network communication (Fibre-optic broadband/Ethernet/Modbus) 
Additionally, for generator and turbine:
  • PLC/SCADA, control – design, I/O-lists (no coding)
  • Serial communication (Modbus and similar) 
As the project is managed in cooperation with our offices in Norway, Singapore and Denmark, you must be willing to travel.
Qualifications: 
  • We expect you to have an education as either a graduate engineer, a Bachelor of Technology Management and Marine Engineering, an electrical technician, a certified electrician or similar.
  • Primarily experience from the machine/process industry
  • Preferably with experience from the oil & gas industry
  • For the position as lead engineer, an additional minimum of 5 years experience from the offshore industry is required
English in speech and writing

Should you be interested, please let me know, along with an indication of your availibility and an update of your CV and I will gladly forward your details to the relevant parties for consideration
CV submissions to:

If you have any colleagues who may be interested in available positions, please feel free to circulate this information
Best regards

David Midwood
Marketing Director
Browning and Henderson International Ltd.
+44 (0)1258 830322

Comments

Popular posts from this blog

DOWNLOAD BUKU: THE TRUTH IS OUT THERE KARYA CAHYO HARDO

  Buku ini adalah kumpulan kisah pengalaman seorang pekerja lapangan di bidang Migas Ditujukan untuk kawan-kawan para pekerja lapangan dan para sarjana teknik yang baru bertugas sebagai Insinyur Proses di lapangan. Pengantar Penulis Saya masih teringat ketika lulus dari jurusan Teknik Kimia dan langsung berhadapan dengan dunia nyata (pabrik minyak dan gas) dan tergagap-gagap dalam menghadapi problem di lapangan yang menuntut persyaratan dari seorang insinyur proses dalam memahami suatu permasalahan dengan cepat, dan terkadang butuh kecerdikan – yang sanggup menjembatani antara teori pendidikan tinggi dan dunia nyata (=dunia kerja). Semakin lama bekerja di front line operation – dalam hal troubleshooting – semakin memperkaya kita dalam memahami permasalahan-permasalahan proses berikutnya. Menurut hemat saya, masalah-masalah troubleshooting proses di lapangan seringkali adalah masalah yang sederhana, namun terkadang menjadi ruwet karena tidak tahu harus dari mana memulainya. Hal ters...

Leak Off Test

Prinsipnya LOT (leak off test) dilakukan untuk menentukan tekanan dimana formasi mulai rekah. Tujuannya: 1. Menentukan MASP (Max. Allowable Surface Pressure). Yaitu batasan max surface pressure yg boleh kita terapkan selama drilling operation, tanpa mengakibatkan formasi rekah (fracture). 2. Dengan mengetahui MASP, berarti juga kita bisa mengetahui Max. mud weight yg boleh kita terapkan selama drilling operation, tanpa mengakibatkan formasi rekah (fracture). 3. Menentukan Kick Tolerance. Yaitu maximum kick size yg masih bisa kita tolerir untuk dihandle. Parameter ini nantinya juga berperan untuk menentukan depth casing shoe yang aman dari sudut pandang well control issue. 4. Mengecek kualitas sealing antara cement dengan casing Tanya - BGP HSESupv. BGP.HSESupv@petrochina Dear all Saat masih di rig dulu saya sering mendengar istilah leak off test. dimana step2nya kira kira sebagai berikut 1. Cementing Job 2. TSK ,masuk string dan bor kurang lebih 3 meter dibawah shoe. 3. dilakukan ...

Shutdown System

Apa yang membedakan antara PSD dan ESD? Secara umum keduanya berfungsi "membawa" sistem pemroses ke "keadaan yang lebih aman". Namun secara spesifik PSD lebih ditujukan kepada sebab sebab Process Specific seperti: Overpressure di bagian hilir kompressor, temperatur tinggi di heater untuk fuel gas, level yang terlau rendah di slug catcher, dst. Sementara ESD lebih ditujukan untuk menanggulangi dampak dari suatu kejadian yang sudah terjadi: misalnya gas yang telah bocor, kebakaran kecil di technical room, kebocoran minyak di pipeline, dst. Kedua jenis shutdown ini dapat pula dipicu oleh spurious trip atau gagalnya sistem shutdown tanpa sebab sebab yang diketahui dengan jelas. lebih rendah levelnya dari PSD ialah USD, atau Unit shutdown. Perlu dicamkan penamaan bisa berbeda beda antar company, misalnya ada yang menyebutnya sebagai ESD1, ESD2, ESD3 dan seterusnya, ada yang menyebutkannya sebagai ESD, PSD, USD dan seterusnya. Tidak penting, yang penting pahami betul fi...